SmartSeries Literature |
Product Briefs |
Please call (800) 909-9283 or email support@aquatrac.com to request Product Briefs for the SmartSeries product.
|
|
User Manuals |
25. |
|
|
ASMAN41.doc |
Operating Manual for the SmartAS Coolint Tower controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
26. |
|
|
ASMAN41B.doc |
Operating Manual for the SmartAS Boiler controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
27. |
|
|
FLXMAN41.doc |
Operating Manual for the SmartFlex Cooling Tower controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
28. |
|
|
FLXMAN41B.doc |
Operating Manual for the SmartFlex Boiler controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
41. |
|
|
Driver_OP_Ext.pdf |
User Manual for the 'OP_Ext Driver' card (The 'OP_Ext Driver' measures a remote pH sensor connected to a Multiflex, Aegis, or SmartSeries (Flex/AS) controller). Discusses Installation, Configuration, and Specification on the OP_Ext Driver.
back to Literature Categories |
42. |
|
|
Aquatrac_TVRemoteUserGuide.pdf |
User Manual for the SmartSeries (Flex/AS) TV-Remote Control. Discusses the definitions of each functional button on the TV-Remote so you can interact with the SmartFlex or SmartAS controller without the need for a computer.
back to Literature Categories |
|
Application Notes |
1. |
|
|
HowToSetupComputerIPAddress.pdf |
(Adobe PDF) Instructions on how to configure the IP Address of your computer so that you can communicate (via web browser and/or Trackster) with a controller.
back to Literature Categories |
4. |
|
|
AN010-01_Snubbers.pdf |
Application Note that explains what a ‘snubber’ is and why they are required on some blowdown valves to prevent controller resets and controller power relay failures.
back to Literature Categories |
5. |
|
|
AN010-02_Sensor_PM.pdf |
Application Note on Preventative Maintenance for Cooling Tower Sensors. Lists sensors with recommended calibration, cleaning and replacement schedules
back to Literature Categories |
6. |
|
|
AN010-03_ORP_Sensor_Test.pdf |
Application Note on ORP Sensors Electrical Testing. Details electrical testing to identify ORP sensor failures
back to Literature Categories |
7. |
|
|
AN010-04_NT_Restore.pdf |
Application Note on restoring NT Networks. When the Master controller is replaced on a network of controllers with the NT option, the network must be restored at the Master and at each Slave controller. This application note details the NT removal and re-installation sequence.
back to Literature Categories |
8. |
|
|
AN010-05_Rate_to_Volume.pdf |
Application Note on Rate-to-Volume Conversion And Control for SmartSeries (Flex/AS) controllers. Details converting 4-20ma on Rate to Volume for the ON/OFF control of chemical feed pumps.
back to Literature Categories |
9. |
|
|
AN010-06_Variable_Cycles.pdf |
Application Note on Variable Cycle Special Control for SmartSeries controllers. Variable Cycles allows up to three sets of cycle control setpoints based on ranges of Make-Up Conductivity.
back to Literature Categories |
10. |
|
|
AN010-07_FV_Inventory.pdf |
Application Note on Feed Verification Inventory-ppm tracking for SmartSeries (Flex/AS) controllers.
back to Literature Categories |
11. |
|
|
AN010-08_FV_Installation.pdf |
Application Note on Feed Verification Meter Installation for SmartSeries controllers. Details installation of the Feed Verification Meter required for inhibitor feed verification function.
back to Literature Categories |
12. |
|
|
AN010-09_Paddle_Flowswitch.pdf |
Application Note which Provides source and part number information for the older, 1/2in NPT paddle type flow switches Aquatrac Part Number A261400; used in Smart3 and earlier version of S1T series controllers.
back to Literature Categories |
13. |
|
|
AN010-11_GL_Toroidial.pdf |
Application Note on Toroidal Non-Contact Conductivity Sensors. Details adding a third party, Great Lake Instruments, toroidal, non-contact conductivity sensor to an existing Flex or ‘AS’ series controller.
back to Literature Categories |
14. |
|
|
AN010-12_Troubleshoot_Boilers.pdf |
Application Note on Boiler Blowdown Conductivity Tracking. Details the causes, symptoms and fixes for controller boiler conductivities, which do not track actual, measured boiler conductivity.
back to Literature Categories |
15. |
|
|
AN010-15_pH_Temp.pdf |
Application Note on Temperature and Control of pH. Discusses Cooling Tower applications where thermal effect causes water treatment operational problems.
back to Literature Categories |
16. |
|
|
AN010-16_4-20mA_Troubleshooting.pdf |
Application Note on Current Loop Function and Troubleshooting. Discusses the troubleshooting self powered, DC isolated current loops.
back to Literature Categories |
17. |
|
|
AN010-17_4-20mA_Loop_Calib.pdf |
Application Note on Current Loop Calibration. Details calibration of controller powered, DC isolated current loops.
back to Literature Categories |
18. |
|
|
AN010-21_Manual_Status_Config.pdf |
Application Note on Installing Manual Interlocks in SmartSeries controllers. Defines switch sources and wiring details for mounting toggle switches in Aquatrac ‘AS’ and Flex series controller enclosures.
back to Literature Categories |
19. |
|
|
AN010-22_Loop_Isolators.pdf |
Application Note on Installing Loop Isolators for SmartSeries controllers. Details the installation of a 4-20mA current loop isolator for use with Aquatrac’s ‘Flex’ & ‘AS’ series controllers.
back to Literature Categories |
20. |
|
|
AN010-23_Fail_Safe_Chem_Feed.pdf |
Application Note on Fail Safe Acid & Oxidant Feeds. Details the installation of fail-safe hardware for acid & oxidant feeds.
back to Literature Categories |
21. |
|
|
AN010-24.pdf |
Application Note on Loop Powered, Non-Contact Conductivity Measurement for SmartSeries controllers. Details the installation & operation of Part NCCS-10K, Loop powered, non-contact, conductvity sensor & sensor entry, Part Hdr_CN.
back to Literature Categories |
23. |
|
|
AN010-24_NCCS-10K_Config.pdf |
Application Note on Loop Powered, Non-Contact Conductivity Measurement. Details the installation and operation of Part NCCS-10K, Loop powered, non-contact, conductvity sensor and sensor entry, Part Hdr_CN.
back to Literature Categories |
24. |
|
|
AN010-25_Time_Cycle_Config.pdf |
Application Note on Timed Cycling Special Control. Details the operation of the ‘TC’, Timed Cycling, chemical feed pump intermittent feed, special control.
back to Literature Categories |
25. |
|
|
AN010-26_Time_Modulation_Config.pdf |
Application Note on Time Modulation Special Control. Details the operation of the ‘TM’, Time Modulation, chemical feed pump duty cycle special control.
back to Literature Categories |
26. |
|
|
AN010-27_Fail_Safe_Acid_Feed.pdf |
Application Note on Redundant Acid OverFeed Protection. Details the installation of fail-safe hardware for acid pumps.
back to Literature Categories |
27. |
|
|
AN010-28_WM_Switching_Relay.pdf |
Application Note on Limiting Waste Water Volume. Details the installation of a latching relay for switching flow between a waste water plant and drain.
back to Literature Categories |
28. |
|
|
AN010-31_Powering_Current_Loops.pdf |
Application Note on Powering Current Loops. Details the wiring of a 4-20mA current loop powered by an 18-24VDC power cube located in the controller enclosure.
back to Literature Categories |
33. |
|
|
AN_T005.pdf |
Application Note on Powering Thermal Flowswitches Connecting an Auxiliary DC Supply. Details using a 15VDC, 300mA supply to power a Flowline thermal flowswitch.
back to Literature Categories |
35. |
|
|
AN_T011.pdf |
Application Note on Sharing a phone line among 2 or more controllers. Details how Two or more Aquatrac controllers with modems can share a common phone line using a commercially available phone switch.
back to Literature Categories |
|
Technical Manuals |
11. |
|
|
FLX-AS_TechMan_R1.doc |
SmartSeries (Flex/AX) Technical manual details controller functions not covered in the controller Installation and Maintenance manual for the Smart Flex and Smart Automated Service, 'AS' series controllers. Discusses Troubleshooting; Serial/Modem communication; Rate-To-Volume; Variable Cycles; Feed Verifictaion; Time Modulation; Timed Cycling; and more.
back to Literature Categories |
|
Backplane Drawings |
Please call (800) 909-9283 or email support@aquatrac.com to request Backplane Drawings for the SmartSeries product.
|
|
Header Drawings |
2. |
|
|
Hdr_CO_F.pdf |
Sensor Installation Header for Conductivity, Temperature, and Flowswitch.
back to Literature Categories |
3. |
|
|
Hdr_CO_OR_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, ORP, Corrosion Rate, and Flowswitch
back to Literature Categories |
4. |
|
|
Hdr_CP_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, Corrosion Rate, and Flowswitch
back to Literature Categories |
5. |
|
|
Hdr_CP_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, and Flowswitch
back to Literature Categories |
6. |
|
|
Hdr_CP_FF_HP.pdf |
Sensor Installation Header for Conductivity, Temperature, and Flat-faced double junction pH
back to Literature Categories |
7. |
|
|
Hdr_CP_OR_CR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, ORP, Corrosion Rate, and Flowswitch
back to Literature Categories |
8. |
|
|
Hdr_CP_OR_F.pdf |
Sensor Installation Header for Conductivity, Temperature, pH, ORP, and Flowswitch
back to Literature Categories |
9. |
|
|
Hdr_OR.pdf |
Sensor Installation Header for ORP Sensor and Solution Ground
back to Literature Categories |
10. |
|
|
Hdr_OR_F.pdf |
Sensor Installation Header for ORP Sensor and Flowswitch
back to Literature Categories |
11. |
|
|
Hdr_PH.pdf |
Sensor Installation Header for pH Sensor and Solution Ground
back to Literature Categories |
12. |
|
|
Hdr_PH_F.pdf |
Sensor Installation Header for pH Sensor and Flowswitch
back to Literature Categories |
|
Installation and Wiring |
|
5. |
|
|
ASMAN41.doc |
Operating Manual for the SmartAS controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
6. |
|
|
ASMAN41B.doc |
Operating Manual for the SmartAS Boiler controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
7. |
|
|
FLXMAN41.doc |
Operating Manual for the SmartFlex Cooling Tower controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
8. |
|
|
FLXMAN41B.doc |
Operating Manual for the SmartFlex Boiler controller. Discusses wiring up sensors, pumps, valves, meters, solenoids; Configuration of inputs and output; Operation and Maintenance; Commissioning
back to Literature Categories |
12. |
|
|
FieldWire1A.pdf |
Field Wiring guide for SmartAS Boiler Blowdown. Controller: SAB-B4-TB for 1 to 4 boilers & 1 to 4 chemical feed pumps.
back to Literature Categories |
13. |
|
|
FieldWire2A.pdf |
Field Wiring guide for SmartAS Cooling Towers. Controller: SAT
back to Literature Categories |
14. |
|
|
FieldWire2B.pdf |
Field Wiring guide for SmartAS Cooling Towers. Controller: SAT-CP-T2-F-AD
back to Literature Categories |
15. |
|
|
FieldWire41.pdf |
Field Wiring guide for SmartAS Cooling Towers. Controller: SAT (SAT-CP-OR-F-RM E4- Hardwired)
back to Literature Categories |
16. |
|
|
FieldWire_AD10Amp.pdf |
Field Wiring guide for SmartAS Cooling Towers. Controller: SAT-CP-F-RM-AD 10 Amp Alarm Contacts
back to Literature Categories |
17. |
|
|
FieldWire_CM.pdf |
Field Wiring guide for SmartAS Condensate Monitor. Controller: SAB-B4 Condensate Monitor - Thermally Compensated Conductivity Monitoring
back to Literature Categories |
18. |
|
|
FieldWire_ph2.pdf |
Field Wiring guide for SmartAS Cooling Towers. Controller: SAT-2PH (External Buffer Amplifier)
back to Literature Categories |
19. |
|
|
FieldWire_ph3.pdf |
Field Wiring guide for SmartAS Cooling Towers. Controller: SAT-3PH Dual, External Buffer Amplifiers
back to Literature Categories |
20. |
|
|
FieldWireB2_XC.pdf |
Field Wiring guide for SmartAS Boiler Blowdown. Controller: SAB-B2-XC Controller for 2 boilers & Condensate Bypass
back to Literature Categories |
21. |
|
|
FieldWireB_cont_XC.pdf |
Field Wiring guide for SmartAS Boiler Blowdown. Controller: SAB Continuous Conductivity control for Boilers
back to Literature Categories |
|
Upgrade Manuals |